STRUCTURAL ASSESSMENT AND REHABILITATION (SAR):
  • In-situ quality assessment, durability investigation and residual life assessment of concrete structures
  • NDT including durability testing for Reinforcement Corrosion due to carbonation and chloride attack
  • Distress investigations of buildings, bridges, dams, power plants, chimney, silo etc. deteriorated dueto aggressive environment or fire damaged structure
  • Consultancy for repairs/rehabilitation & retrofitting
  • Proof Checking of Structural Design
  • Service Life Design for concrete structures
THIRD PARTY QUALITY ASSURANCE:
  • Technical Audit (TA), Quality Assurance & Quality Control (QA/QC) and Third-Party Quality Audit (TPQA) of new constructions-residential, commercial & institutional Buildings; Flyovers, Concrete roads, Bridges etc.
  • Consultancy for Buildings using Precast Technology
  • Consultancy for fly ash based building products such as fly ash bricks, paver blocks, kerb stones, aerated concrete block etc.
CONCRETE TECHNOLOGY: Testing of Concrete Making Materials
  • CementandcementitiousMaterialssuchasOPC,PPC,PSC,FlyAsh,Slag,etc.
  • Aggregates – Complete physical and chemical analysis and Alkali-AggregateReactivity
List of Equipments
S.NoName of the EquipmentPurpose
1CONCRETE PAN MIXER- CAPACITY: 40 LITERS AIMIL MAKECONDUCTING CONCRETE MIX PROPORTION TRAILS
2CONCRETE PAN MIXER- CAPACITY: 250 LITERS AIMIL MAKECONDUCTING CONCRETE MIX PROPORTION TRAILS
3CONCRETE SLUMP CONE TESTFRESH CONCRETE WORKABILITY TEST
4COMPACTION TEST OF FRESH CONCRETEFRESH CONCRETE WORKABILITY TEST
5VEE-BEE CONSISTOMETER FOR CONCRETEFRESH CONCRETE WORKABILITY TEST
6SELF COMPACTING CONCRETE (SCC) WORKABILITY EQUIPMENT - SLUMP CONE WITH TABLE L-BOX V-BOX & U-BOXSCC FRESH CONCRETE WORKABILITY TEST
7CEMENT CONCRETE CUBES (150×150×150mm)CC CUBE’S FOR CONCRETE COMPRESSIVE STRENGTH
8CEMENT CONCRETE BEAMS (150×150×700mm)CONCRETE FLEXURAL STRENGTH AND CONCRETE SPLIT COMPRESSIVE STRENGTH
9ELECTRONIC WEIGHING BALANCE – CAPACITY 150KG, 15KG AND 5KGFOR CONCRETE TESTING
10C.C. CUBES VIBRATING TABLEFOR MAKING FRESH CONCRETE CC CUBES
11C.C. CUBES VIBRATING NEEDLEFOR MAKING FRESH CONCRETE CC CUBES
12CC CUBES CONCRETE WATER CURING TANKCC CUBES WATER CURING
13HOT AIR OVENTESTING
14ACTM-2000KN – MAKE: CONTROL’S-GERMANYTESTING OF CC CUBES COMPRESSIVE STRENGTH
15ACTM-3000KN – MAKE: AIMIL ATTACHED WITH FLEXURAL STRENGTH AND SPLIT TENSILE STRENGTHTESTING OF CC CUBES COMPRESSIVE STRENGTH AND CC BEAMS FLEXURAL STRENGTH AND SPLIT TENSILE STRENGTH
16CORE EXTRACTION TESTING AND EVALUATION – 60mm, 75mm & 100mmHARDENED CONCRETE CORE EXTRACTION AND TESTING
17PROFOMETERHARDENED CONCRETE COVER AND LOCATION OF THE STEEL REBARS
18REBOUND HAMMER – NDT TESTINGLIKELY COMPRESSIVE STRENGTH OF HARDENED CONCRETE
19ULTRASONIC PULSE VELOCITYQUALITY, INTEGRITY AND HOMOGENEITY OF CONCRETE
20HALF-CELL POTENTIAL TESTERPROBABILITY OF REBAR CORROSION
21RESISTIVITY METERRESISTANCE OF CONCRETE TO PERMEATION OF WATER
22CRACKOSCOPEWIDTH OF CRACKS
List of Recent Projects:
S.NoName of the Project
1Third Party Quality Assurance (TPQA) for the work of Chemical & Materials and Metallurgical Engineering Buildings at NIT Warangal
2Third Party Quality Control Assurance (TPQA) for Construction Dr. B.R. Ambedkar Learning Center and Renovation of IT Theme Centre at NIT Warangal
3TPQA Services of Academic Complex at IIT Madras at Chennai-36 at IITM at Chennai
4TPQA of 765Kv D/C Vemagiri-Chilakaluripeta (251.61Km) 765 Kv D/C Chilakaluripeta–Kadapa (305.5Km) 400Kv D/C Kadapa–Madhugiri (238.4Km) 400Kv D/C Palasa-Garividi (145.8Km) Transmission lines projects of Power Grid Corporation Limited Secunderabad
5Third Party Field Quality Field Quality Inspection for +/- 800 KV Raigarh-Pugalur Transmission Line SR-1 Portion of Power Grid Corporation of India Limited Kurnool CAO
6Third Party Field Quality Inspection at random for +800Kv Raigarh-Pugalur Transmission lines (SR-I Portion) against Specification No SR-I/C&M/WC-1856-5A/2017-TW 05 Jangoan Telangana State
7Construction of Boys Hostel for CIPET, IDA, Phase-II, Cherlapally, Hyderabad
8Construction of Skill Development Centre and Hostel Blocks at Chellakere campus Challakere district-Chitradurga Karnataka
9TPQA for the Work of “Design & Construct SC/ST hostel beneficiaries and associated building for NIEPMD with PRECAST TECHNOLOGY” at Muttukadu Chennai
10Condition Assessment Studies of TG foundations (3 No’s, 500MW each) at Rihand Super Thermal Power Station, Rihand Nagar, Uttar Pradesh
11Condition Assessment of Structural Concrete using Non-Destructive Technique including preparation of BOQ cost estimate & Third-Party Quality Assurance during repair of Cooling Tower Unit I & II in PP-III at NSPCL Bhilai
12Condition Assessment and Recommendations on Repair & Restoration Measures of Fairlie Warehouse at Kolkata Port Trust (KoPT), Kolkata
13Condition Assessment Study of RCC Chimney Unit #4, 5 & 6 at NTPC Ramagundam Super Thermal Power Station, Ramagundam, Telangana
14Condition Assessment Studies and recommendations on repair & restoration/strengthening measures of Track Hopper I & II at Farakka Super Thermal Power Station, NTPC Farakka
15Condition Assessment of TG foundation of Units 1/2/3 (200MW) & Unit-5/7 (500MW) units (Total 5 No’s) NTPC Ramagundam Super Thermal Power Station Ramagundam Telangana
16Condition Assessment of 2 Nos RCC IDCT structures of NTECL Vallur Thermal Power Station at Vallur Tamil Nadu
17Evaluation of Treated Drilling Waste material obtained from Krishna Godavari Basin, Andhra Pradesh for use as optimum replacement for making fly ash bricks by SAR Chandra Environ Solutions Pvt. Ltd. Kakinada
18Conducting Concrete Mix Proportions M50A20 Grades (2 Nos) of Concrete using OPC-53 Grade chemical admixture for civil works of Precast Lining Segments for Srisailam Tunnel Project
19Evaluation of Materials and Conducting Concrete Mix Proportion M25A20 Grade of Concrete using chemical admixture for civil works of supply, installation, erection and commissioning of VFD System of ID Fan of 500 MW Units, NTPC Ramagundam STPS Stage-II (3×500MW)